SUPER MEGOHM METER
SM7120
Exclusive Academic Offer
The Hioki SM Series Super Megohm Meters are high resistance and ultra low current inspection devices with a 0.1 fA resolution to offer precise testing on production lines. To accommodate vehicle components with increasingly high breakdown voltages, the SM7120 is the first insulation tester in the world to be able to output a measurement voltage of 2000 V. |
Model No. (Order Code)
Note: Measurement leads are not included. |
---|
Key Features âĒ 300 times better noise resistance |
---|
Flexible, Multipurpose Design SUPER MEGOHM METER
Flexible, Multipurpose Design |
|
2000V / 2*10^19 ÎĐãDisplay
Perfect for EVs and other high-voltage applications |
|
1/60 Variability, 300x Noise Resistance
Stability (repeatability) against power supply noise and external noise has improved dramatically due to a combination of new Super Megohm floating circuitry and triaxial connectors. |
|
Min. 6.4 ms High-Speed Inspection
6.4 ms = 4.1 ms measurement + 2.3 ms contact check |
|
High-Performance Contact Checks
[Low capacity contact checks] [2-band selection] |
|
Electrodes for a Variety of Materials and Uses
For Electronic Components |
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Number of channels | 1 ch |
---|---|
DC current measurement | 20 pA range (0.1 fA resolution), Accuracy: ¹(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ¹(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA resolution), Accuracy: ¹(0.5 % of rdg. +20 dgt.) 20 nA range (100 fA resolution), Accuracy: ¹(0.5 % of rdg. +10 dgt.) 200 nA range (1 pA resolution), Accuracy: ¹(0.5 % of rdg. +10 dgt.) 2 ΞA range (10 pA resolution), Accuracy: ¹(0.5 % of rdg. +10 dgt.) 20 ΞA range (100 pA resolution), Accuracy: ¹(0.5 % of rdg. +10 dgt.) 200 ΞA range (1 nA resolution), Accuracy: ¹(0.5 % of rdg. +10 dgt.) *2 mA range (1 nA resolution), Accuracy: ¹(0.5 % of rdg. +30 dgt.) (1) Measurement speed SLOW2 (internal integration time 13PLC) (2) At a temperature of 23 °C ¹5 °C with humidity of 85% rh (3) 2 mA range (Measurement speed FAST only) |
Resistance measurement capabilities | 50 ÎĐ to 2 Ã 10 ^19 ÎĐ Note: Resistance measurement accuracy is defined by the current range accuracy and voltage setting accuracy. |
Setting voltage range (Accuracy) | 0.1 to 100.0 V, 100 mV resolution, Accuracy: Âą0.1 % of setting Âą0.05% f.s. 100.1 to 1000 V, 1 V resolution, Accuracy: Âą0.1 % of setting Âą0.05% f.s. |
[SM7120 only] 1000 to 2000 V,1 V resolution, Accuracy: Âą0.2 % of setting Âą0.10% f.s. |
|
Current Limiter | 0.1 to 250.0 V: 5/ 10/ 50 mA, 251 to 1000 V: 5/ 10 mA, to 2000 V:1.8 mA |
Measurement time setting | Delay: 0 to 9,999 ms |
Functions | Comparator, averaging, self-calibration, jig Capacity open correction, cable length correction, surface resistivity, volume resistivity, voltage monitor, contact check |
Program function | 10 types of discharge, charge, measure and measurement sequence discharge patterns can be programmed. |
Display | LCD (8 lines of 30 characters), with backlight, High voltage warning indicator |
Interfaces | USB, RS-232C, GP-IB, EXT I/O (NPN/PNP can be switched) |
Power supply | 100 to 240V AC , 50/60 Hz, 45 VA |
Dimensions and mass | 330 mm (12.99 in)W Ã 80 mm (3.15 in)H Ã 450 mm (17.72 in)D, 5.9 kg (208.1 oz) |
Accessories | Power cord Ã1, Instruction manual Ã1, CD-R (Communications command instruction manual, USB driver) Ã1, EXT I/O male connector Ã1, Short plug Ã1 |
Catalog: SUPER MEGOHM METER SM7110, SM7120, SM7420 | Download PDFÂ [3MB] | English |
For more information, click here