MEMORY HiLOGGER
LR8400 Series
10ms Simultaneous Sampling
Exclusive Academic Offer
Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, resistance, humidity and pulse signals, providing complete isolation between channels and strong noise resistance. The LR8400 Series logs data at 10ms speeds across 30 channels simultaneously, is expandible up to 60 channels, and features a bright color LCD for crystal clear waveform displays. Key Features |
Model No. (Order Code)
Caution: Built-in units cannot be removed or changed. The Battery pack Z1000 is sold separately |
Product Video
|
|
How to Analyze the Temperature Efficiency of a Refrigerator using the Hioki LR8400 Series Memory HiLogger Use the Hioki LR8400 Memory HiLogger series to analyze the temperature difference between the external body and internal cavity of a refrigerator. Cold chain temperature management is particularly important for maintaining the integrity of storage systems for vaccines, perishables, and other temperature-sensitive products. The temperature of the refrigeration equipment at various internal and external points must be constantly monitored for sudden thermal excursions. Notwithstanding the multi-channel capabilities of the LR8400, the time scale axis of the data logger can be freely adjusted to display measured waveforms first as a trend in terms of seconds, then in terms of minutes, while still recording. Observe temperature changes from the very beginning and fast-forward to the present right on the screen. |
|
A multichannel data logger that’s ideal for battery, automotive, and environmental measurement For applications such as |
|
Portable data logger with 30 standard channels expandible to 60 channels Heat flow and temperature gauges can be displayed simultaneously for data measured with the Heat Flow Logger LR8432-20. The instrument comes with 30 channels as standard, but another two 15 channel input units can be added to expand the total number of channels to 60. The instrument also features 8 channels of pulse and digital input. Note: The units provided with the unit as standard cannot be removed. |
|
A data logger with a sampling speed of up to 10 ms The development of hybrid and electric automobiles requires instruments that can measure abrupt load changes. The instrument can reliably capture even abrupt changes in load since it can measure channels 1 to 15 in 10 ms. Note: Measurements on channels 31 to 60 provide 50-ms sampling. |
|
A high-withstand-voltage data logger with a maximum rated channel-to-channel and channel-to-ground voltage of 300 V The HiLOGGER measures not only fuel cells, but also batteries for UPS (uninterruptible power supplies) devices used in buildings as well as batteries consisting of cells and packaging connected in stacks that require multi-point measurements. In such measurements, high voltage for the whole stack is applied between channel-to-channel and channel-to-ground. The universal unit delivers safe measurement thanks to a high-withstand-voltage design featuring a maximum rated channel-to-channel voltage of 300 V DC. Note: Isolation between channels is possible through the use of semi-conductor relays. |
|
Included PC application with measurement and analysis functionality The supplied Logger Utility software enables processing of measurement data on a PC. Use the supplied Logger Utility software to record data on a PC in real-time. Connect the PC to the HiLOGGER using USB or via LAN. |
|
Get results from the job site in real-time, GENNECT CROSS SF4000 Capture data on the PC while testing remotely |
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Analog input Universal unit LR8501 Actual functionality will depend on combination of units installed Note: Isolated from each channel to chassis | [No. of channels] 15 analog channels; isolated scanning method input (4 terminals: push-button type) [Voltage] ±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between channels and from each channel to chassis) [Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K, J, E, T, N, R, S, B, W,) Max. resolution 0.01 ˚C, (Isolated between channels and from each channel to chassis) [Temperature: Pt 100, JPt 100 sensor] -200 ˚C to 800 ˚C, Max. resolution 0.01 ˚C, (Not isolated between channels) [Resistance] 0 Ω to 200 Ω f.s. Max. resolution 0.5 mΩ, (Not isolated between channels) [Humidity] 5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isolated between channels nor from each channel to chassis) [Max. rated voltage between isolated input channels] 300 V DC [Max. allowable input] ±100 V DC [Max. rated voltage from isolated terminals to ground] 300 V AC, DC |
---|---|
Analog input Votage/temp unit LR8500 Actual functionality will depend on combination of units installed Note: Isolated from each channel to chassis | [No. of channels] 15 analog channels; isolated scanning method input (2 terminals: M3 screw type) [Voltage] ±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between channels and from each channel to chassies) [Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01 ˚C, (Isolated between channels and from each channel to chassies) [Pt 100, JPt 100 sensor] [Resistance] Not available [Humidity] 5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isolated between channels nor from each channel to chassies) [Max. rated voltage between isolated input channels] 250 V DC [Max. allowable input] ±100 V DC [Max. rated voltage from isolated terminals to ground] 300 V AC, DC Caution: Max. voltage from terminals to ground without damage |
Pulse, Digital input | [No. of channels] 8 channels, pulse / digital selectable for each channel, M3 screw terminal, not isolated, common ground [Pulse totalization] 0 to 1000 M pulse, 1 range (No-voltage ‘a’ contact; normally open, open collector or voltage input), Max. resolution 1 pulse [Rotation count] 0 to 5000 /n (r/s) f.s. 1 range (same as Pulse totalization input signal condition), resolution 1/n (r/s) Note: “n” is the number of sensor output pulses per revolution, 1 to 1000 [Digital input] Record logical “1” or “0” at each sampling [Max. rated voltage between input channels] Not isolated [Max. allowable input] 0 to 50 V |
Recording intervals | 10 ms to 50 ms, 100 ms to 1 hour, 19 selections (All input channels are scanned within each recording interval.) Note: limited by using channels at 10 ms to 50 ms interval |
Digital filter | Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set) |
Data storage | Internal memory: 8 M-words, Data storage media: CF card or USB memory (Only data recorded to a genuine HIOKI CF card is guaranteed) |
LAN interfaces | 100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or E-mail system |
USB interfaces | USB 2.0 High-speed capable, series mini-B receptacle Functions: Data acquisition using bundled software or PC commands, Transfer data from the CF card to a PC via USB drive mode Note: Data transfer not possible from USB memory sticks |
Display device | 5.7 inch TFT color liquid crystal display (640 × 480 pixel) |
Other functions | Save waveform data in real time to the CF card or USB memory stick, Numerical value calculations, Waveform calculations, and others |
AC Power supply | Using the AC adapter 9418-15 (100 to 240 V AC, 50/60 Hz), 7 VA |
DC Power supply | Using the Battery pack Z1000 (optional accessory), Continuous use 5 hr, External power: 10 to 28 V DC (Please contact your HIOKI distributor for connection cord) |
Dimensions and Mass | 272 mm (10.71 in) W × 182.4 mm (7.18 in) H × 66.5 mm (2.62 in) D, 1.8 kg (63.5 oz), (LR8400-20 main unit, excluding the Battery Pack 370 g/ 13.1 oz) |
Accessories | Instruction manual ×1, Measurement guide ×1, CD-R (data collection software “Logger Utility”) ×1, USB cable ×1, AC adapter 9418-15 ×1 |
Combination status with LabVIEW or MATLAB script
Compatible models | LabVIEW | MATLAB script |
---|---|---|
LR8400-20 | OK | N/A |
LR8401-20 | OK | N/A |
LR8402-20 | OK | N/A |
Catalog: MEMORY HiLOGGER LR8400, LR8401, LR8402 | Download PDF [4MB] | English |
Catalog: DATA LOGGER Selection Guide LR8431, LR8400 series, 8423, LR5000 series | Download PDF [5MB] | English |
Catalog: GENNECT CROSS SF4000 | Download PDF [1MB] | English |
For more information, click here