CLAMP ON POWER LOGGER
PW3360

Portable Power Loggers for Energy Audits and Energy
Conservation
Exclusive Academic Offer

HIOKI Clamp On Power Meters are multi-channel power measuring devices
utilizing clamp sensor input to accurately and safely measure power
on single-phase to three-phase lines. The PW3360 compact 3-Phase
4-Wire energy loggers monitor power demand and other power parameters
to aid in energy audits and validate energy saving measures

Model No. (Order Code)

PW3360-20 English model, main unit only
PW3360-21 English model, with harmonic analysis function
LANUSB2TrueRMS
SDCESDHC

Note: At least one optional current sensor is necessary
to measure current or power parameters. To store
measurement data, use only the guaranteed SD
cards sold by HIOKI.

Key Features

â€Ē Supports single to three-phase, 4-wire circuits
â€Ē Measure between 90V to 780V
â€Ē Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)
â€Ē Slim, compact design that can be placed anywhere
â€Ē Store months of data on SD cards
â€Ē The QUICK SET function guides you in making the right connections
â€Ē Choose PW3360-21 for harmonic measurements up to the 40th order
â€Ē WHM (watt-hour meter) connection checking function installed


Product Video

Navigate clamp-on power logger operation with graphical, easy-to-use displays of wiring procedures

The PW3360’s QUICK SET feature is an on-screen guide that walks you through the setup process, right up to starting measurement. Even if you’re unaccustomed to how clamp-on power loggers work, you’ll be able to easily configure and connect the instrument for 3-phase power measurement. In addition, by alerting you to any wiring mistakes, the device’s “wiring check” function serves to prevent measurement errors that are caused by undetected wiring mistakes.

Power logger functionality for displaying measurement results as a graph so you can review them at a glance

The PW3360 displays recorded measured values as a graph for convenient use in power management. In addition to instantaneous measured values, you can review maximum, minimum, and average values by moving the cursor on the demand and trend graph displays.

A portable power logger that’s small enough to use in a confined cubicle

This power logger is an essential tool for power-saving activities. Thanks to a compact design that weighs just 550 g, it’s easy to take into the field and install in confined locations.

 

Get results from the job site in real-time, GENNECT CROSS SF4000

Capture data on the PC while testing remotely

Learn more

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement line & number of circuits 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement items Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
[PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order
Voltage ranges 600 V AC (Effective measurement range: 90.00 V to 780.00 V)
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
Power ranges 300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracy Voltage : Âą0.3% rdg. Âą0.1% f.s
Current : Âą0.3% rdg. Âą0.1% f.s. + clamp sensor accuracy
Active power : Âą0.3% rdg. Âą0.1% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destination SD memory card, or internal memory at real time
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save items Measurement value save: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data save: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data
Interfaces SD/SDHC memory card
LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
Functions Connection check, Quick Set navigation guide, clock, pulse input
Power supply AC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)
Dimensions and mass 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002
Accessories Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5