DIGITAL PHASE DETECTOR
PD3259-50

Digital Phase Rotation Meter with
Three-Phase Voltage Measurement Functionality

Hioki’s non-contact voltage detection and measurement technology places efficiency and safety as priority considerations with the goal of protecting customers that need to conduct on-site electrical work as part of renovations and expansions of manufacturing plants and buildings.
The PD3259-50 Digital Phase Detector lets you to measure three-phase voltage and detect phase sequence simultaneously by just clipping onto covered cables, ensuring absolutely no contact with metal parts for maximum safety.

CAT IV 600 V

Key Features
â€Ē Wireless support. Transfers measurements to your smartphone or tablet. (Optional Wireless Adapter Z3210 is necessary)
â€Ē World’s first non-metallic contact voltage detection and testing
â€Ē Simply clip onto wire insulation
â€Ē Phase detection check and line-to-line voltage inspection at the same time
â€Ē Easy and intuitive phase detection check with backlight and buzzer
â€Ē Ideal for work certification photos, offering simultaneous display of phase sequence and 3-phase voltage

Note: Only the voltage value is displayed when measuring a single-phase/3-wire circuit.

Model No. PD3259-50

When Z3210 is installed.

Wireless support Wireless communication capability for even greater convenience than PD3259 (legacy model)

Compatible with Wireless Adapter Z3210 (optional).

When the wireless adapter Z3210 is attached to the PD3259-50, you can use BluetoothÂŪ wireless communication.

And using the free app GENNECT Cross, you can check the measurement value, manage the data and creat the report on smartphones and tablets smoothly.

Click here to see fullscreen video

Easy! Just connect the optional Z3210 Wireless Adapter to your Hioki compatible instrument, to make it BluetoothÂŪ ready.

Wirelessly connect Hioki-compliant instruments with a simple connection.
Transmit measured values to your tablet or smartphone.

New function in GENNECT Cross

You can check the unbalance rate and vector diagram from the measurement data of PD3259-50.

*Optional Wireless Adapter Z3210 is necessary.
*scheduled to be upgraded in 2021.
*This is a reference image of the planned completion.

Transport to the ExcelÂŪ file

Open an ExcelÂŪ file and select a cell.
The measured value being held on the instrument’s display will be transferred to the computer and entered into the selected cell.

*Optional Wireless Adapter Z3210 is necessary.
*It will be supported by the 2021 upgrade.

Just clip the wire

The measurement can be taken simply by clipping the wire.

Safe measurement without contact with metal

There is no metal exposure on the sensor.
You can measure safely without touching metal.

Display on a large screen

Phase detection check and line-to-line voltage inspection at the same time.

Light and sound notification

A red light and a continuous buzzer sounds to indicate the Negative phase.

You can switch screens and check the frequency.

Fix the instrument to the wall

The MAGNETIC STRAP Z5020 (option) can be used by fixing the main body of the measuring instrument to the wall.

Color clips are included to help identify the code

Click here to see fullscreen video

How to Use the Hioki Digital Phase Detector PD3259-50

In the past, four steps have been necessary in order to check a 3-phase power circuit: one set of measurements to check the phases with a phase detector, and three line-voltage measurements (one for each phase) made with a tester. The Digital Phase Detector PD3259-50 replaces this process with a single, no-metal-contact measurement step that can be made simply by affixing three clamp sensors. The instrument quickly displays the phase detection results and three phase voltage values.

Basic specifications (Accuracy guarantee period: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year)

AC Current range 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Basic accuracy 45 Hz – 400 Hz: Âą1.0% rdg Âą5 dgt (6.000 mA to 6.000 A), Âą1.5% rdg Âą5 dgt (60.00 A, 200.0 A)
Basic accuracy 15 Hz – 45 Hz, 400 Hz – 2 kHz: Âą2.0% rdg Âą5 dgt
Defined accuracy range: 0.060 mA to 200.0 A
AC Voltage range N/A
Frequency range 15.0 Hz to 2000 Hz
Crest factor 3 (other than 200.0 A range), 1.5 (200.0 A range)
Filter function Cut off frequency: 180 Hz Âą30 Hz at filter ON (-3 dB)
Output function RMS (RMS value output), WAVE (waveform output)
Other functions Max/ Min/ AVG/ PEAK MAX/ PEAK MIN value display, Display value hold and auto hold; Backlight, Auto power save, Buzzer sound, Event count display, Comparator, Simple event recording, Rush current measurement
Display Display refresh rate: 5 times/s
Power supply – AA-size alkaline battery (LR6) × 2; Continuous operating time: 48 hr. (without Z3210 installed), 30 hr. (with Z3210 installed and using wireless communications)
– AC Adapter Z1013 (5 V DC, 2.6 A)
Core jaw diameter φ 40 mm (1.57 in.)
Dimensions and mass 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D, 400 g (14.1 oz.)
Accessories Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
Catalog: CLAMP METER Series Download PDF  [8MB] English
Catalog: AC LEAKAGE CLAMP METER CM4002, CM4003 Download PDF  [āļļ6MB] English