DIGITAL PHASE DETECTOR
PD3259-50
Three-Phase Voltage Measurement Functionality
Hiokiâs non-contact voltage detection and measurement technology places efficiency and safety as priority considerations with the goal of protecting customers that need to conduct on-site electrical work as part of renovations and expansions of manufacturing plants and buildings. CAT IV 600 V Key Features Note: Only the voltage value is displayed when measuring a single-phase/3-wire circuit. |
Model No. PD3259-50
When Z3210 is installed. |
Wireless support Wireless communication capability for even greater convenience than PD3259 (legacy model) Compatible with Wireless Adapter Z3210 (optional). When the wireless adapter Z3210 is attached to the PD3259-50, you can use BluetoothÂŪ wireless communication. And using the free app GENNECT Cross, you can check the measurement value, manage the data and creat the report on smartphones and tablets smoothly. |
|
Easy! Just connect the optional Z3210 Wireless Adapter to your Hioki compatible instrument, to make it BluetoothÂŪ ready.
Wirelessly connect Hioki-compliant instruments with a simple connection. |
|
New function in GENNECT Cross You can check the unbalance rate and vector diagram from the measurement data of PD3259-50. *Optional Wireless Adapter Z3210 is necessary. |
|
Transport to the ExcelÂŪ file Open an ExcelÂŪ file and select a cell. *Optional Wireless Adapter Z3210 is necessary. |
|
Just clip the wire The measurement can be taken simply by clipping the wire. |
|
Safe measurement without contact with metal There is no metal exposure on the sensor. |
|
Display on a large screen Phase detection check and line-to-line voltage inspection at the same time. |
|
Light and sound notification A red light and a continuous buzzer sounds to indicate the Negative phase. You can switch screens and check the frequency. |
|
Fix the instrument to the wall The MAGNETIC STRAP Z5020 (option) can be used by fixing the main body of the measuring instrument to the wall. |
|
Color clips are included to help identify the code |
|
How to Use the Hioki Digital Phase Detector PD3259-50 In the past, four steps have been necessary in order to check a 3-phase power circuit: one set of measurements to check the phases with a phase detector, and three line-voltage measurements (one for each phase) made with a tester. The Digital Phase Detector PD3259-50 replaces this process with a single, no-metal-contact measurement step that can be made simply by affixing three clamp sensors. The instrument quickly displays the phase detection results and three phase voltage values. |
Basic specifications (Accuracy guarantee period: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year)
AC Current range | 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Basic accuracy 45 Hz – 400 Hz: Âą1.0% rdg Âą5 dgt (6.000 mA to 6.000 A), Âą1.5% rdg Âą5 dgt (60.00 A, 200.0 A) Basic accuracy 15 Hz – 45 Hz, 400 Hz – 2 kHz: Âą2.0% rdg Âą5 dgt Defined accuracy range: 0.060 mA to 200.0 A |
---|---|
AC Voltage range | N/A |
Frequency range | 15.0 Hz to 2000 Hz |
Crest factor | 3 (other than 200.0ãA range), 1.5 (200.0ãA range) |
Filter function | Cut off frequency: 180 Hz Âą30 Hz at filter ON (-3 dB) |
Output function | RMS (RMS value output), WAVE (waveform output) |
Other functions | Max/ Min/ AVG/ PEAK MAX/ PEAK MIN value display, Display value hold and auto hold; Backlight, Auto power save, Buzzer sound, Event count display, Comparator, Simple event recording, Rush current measurement |
Display | Display refresh rate: 5 times/s |
Power supply | – AA-size alkaline battery (LR6) Ã 2; Continuous operating time: 48 hr. (without Z3210 installed), 30 hr. (with Z3210 installed and using wireless communications) – AC Adapter Z1013 (5 V DC, 2.6 A) |
Core jaw diameter | Ï 40 mm (1.57 in.) |
Dimensions and mass | 64 mm (2.52 in) W Ã 233 mm (9.17 in) H Ã 37 mm (1.46 in) D, 400 g (14.1 oz.) |
Accessories | Connection Cable L9097 à 1, USB Cable à 1, Carrying case C0203 à 1, Instruction manual à 1, Operating Precautions à 1, AA-size alkaline battery (LR6) à 2 |
Catalog: CLAMP METER Series | Download PDFÂ [8MB] | English |
Catalog: AC LEAKAGE CLAMP METER CM4002, CM4003 | Download PDFÂ [āļļ6MB] | English |