MEMORY HiCORDER
MR8741
Generation,
High-speed 16-channel/Isolated Multi-channel System
Recorders (rack-mounted)
The MR8741 is rack-mountable data acquisition system that delivers high-speed, multi-channel measurements over maximum of 16 channels. The MR8990 DVM module is a 2-channel input unit for the MR8741 for measuring minute fluctuations in output from sensors in automobiles and other equipment and voltage fluctuations in devices such as batteries at high levels of precision and resolution. Use with the Arbitrary Waveform Generator Unit U8793 to create a function generator, arbitrary waveform generator, and waveform measurement in a single device. Key Features *Screen monitoring and remote operation available via Internet browser. For faster and more convenient remote operation, we recommend using the Hioki 9333 LAN Communicator. Model No. (Order Code)
Main unit MR8740/MR8741 cannot operate alone. Use up to 4 units of 8971 with MR8740; not compatible with MR8741. |
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Max. Number of channels | 16 ch analog + 16 ch logic, or 10 ch analog + 64 ch logic (when used with built-in logic input + plug-in logic unit 8973 Ã 3) |
---|---|
Number of slots | 8 slots (Max. 8) [Limitation on number of slots] cannot use Current Unit 8971 When using the Logic Unit 8973: Max. 3 |
Number of logic channels | 16 ch logic (Logic probe terminal GND share a common GND with chassis. ) on condition that DVM Unit MR8990 is used on slots 1 and 2, cannot use built-in logic input [Limitation on using built-in logic input] (with logic measurement ON) âĒ Measurement resolution on slots 1 and 2 is limited up to 12 bits âĒ Cannot use Frequency Unit 8970 on slots 1 and 2 |
Measurement ranges (20 div full scale) | 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966) 5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990) |
Max. allowable input | 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage) |
Max. rated voltage to earth | 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage) |
Frequency characteristics | DC to 5 MHz (-3 dB, when using 8966) |
Time axis (MEMORY operation) | 5 Âĩs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expansion: 3 stages from Ã2 to Ã10; compression: 13 stages from 1/2 to 1/20,000 |
Measurement functions | Memory (high-speed recording), FFT, Recorder |
Memory capacity | 16 MW/ch (fixed), total of 256 MW installed |
Removable storage | USB memory stick (USB 2.0) |
Display | None (1 digital DVI terminal, 800 Ã 600 dots) |
External interfaces | [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server) [USB] USB 2.0 Series A receptacle à 2 (mouse operation) |
Power supply | 100 to 240 V AC, 50/60 Hz (120 VA max.) |
Dimensions and mass | 350 mm (13.78 in)W Ã 160 mm (6.30 in)H Ã 320 mm (12.60 in)D, 5.4 kg (190.5 oz) (main unit only) |
Accessories | Instruction manual Ã1, Application disk (Wave viewer Wv, Communication commands table) Ã1, Power cord Ã1 |
LabVIEW and MATLAB support
Compatible models | LabVIEW | MATLAB script |
---|---|---|
MR8740 | Available | Available |
MR8741 | Available | Available |
Catalog: iPad App for Memory HiCorder HMR Terminal | Download PDFÂ [1MB] | English |
Catalog: MEMORY HiCORDER MR8740, MR8741 | Download PDFÂ [4MB] | English |
Catalog: Waveform Generator System U8793,MR8847A | Download PDFÂ [2MB] | English |
Catalog: Digital Multi-Module (DMM) Station MR8990+MR8741/MR8740 | Download PDFÂ [2MB] | English |
For more information, click here