CLAMP ON SENSOR
9695-02

For measuring load current, voltage output sensor
50 A AC
Exclusive Academic Offer

Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9695-02 is a 50A AC clamp sensor with voltage output for measuring load current.

CAT III 300V
For power meters and power loggers (may require the 9219)

Key Features
â€Ē High Âą0.3% accuracy
â€Ē For inverter devices or commercial power lines
â€Ē Fits in narrow spaces due to compact design

Model No. (Order Code)

9695-02 For the PW3198 and similar products

Note: Supports power quality analyzers, power meters and clamp logger LR5051 (50 A sensor only)

DCNotCE

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
f.s. is the sensor’s rated measurement current value.

Rated measurement current 50 A AC
Max. measurement current Continuous 60 A (45 to 66 Hz)
Output rate 10 mV AC/ A
Amplitude accuracy (45 to 66 Hz) Âą0.3 % rdg. Âą0.02 % f.s.
Phase accuracy ¹2° (45 Hz to 5 kHz)
Amplitude frequency characteristics Within Âą1% at 40 Hz – 5 kHz (deviation from amplitude accuracy)
Max. rated voltage to earth 300 V AC rms or less (Insulated conductor)
Measurable conductor diameter φ 15 mm (0.59 in) or less
Operating temperature and humidity 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
Dimensions and mass 50.5 mm (1.99 in)W × 58 mm (2.28 in)H × 18.7 mm (0.74 in)D, 50 g (1.8 oz)
Output terminal : M3 terminal (outside 3 mm, 0.12 inch diameter)
Option: Connection cable 9219 (3 m, 9.84 ft length)

Â