CLAMP ON PROBE
9132-50

Simply Connect to a Tester or Recorder to Easily
Measure Large Currents

Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9132-50 is a multi-range 1000A AC voltage output clamp sensor for capturing waveforms with DMMs and Memory HiCorders. Measure AC current on live power lines without needing to cut the wire.

CAT III 600V

Key Features
â€Ē Economical clamp sensor for waveform recording with Memory HiCorders
â€Ē Choose from up to six general-purpose ranges

Model No. (Order Code)

9132-50 BNC output terminal

Note: For commercial power lines, 50/60 Hz (separate power supply not required).

CE

Basic specifications (Accuracy guaranteed for 1 year)

Rated current 20 A to 1000 A AC, 6 ranges
Accuracy Âą3 % rdg. Âą0.2 % f.s. (45 to 66 Hz)
Frequency characteristics Add to amplitude accuracy for frequencies from 40 to 1 kHz: Âą 1 % rdg.
Output rate 0.2 V AC f.s. (f.s. = setting rage)
(Connect to a voltage input device providing a high input impedance of 1 MÎĐ)
Max. allowable input 1000 A rms continuous (all ranges)
(For 40 Hz to 500 Hz: 100 %, and for 500 Hz to 1 kHz: within 90 % of derating)
Max. rated voltage to earth 600 Vrms (50/60 Hz, CAT III)
Core diameter φ55 mm (2.17 in), or 20 mm (0.79 in) × 80 mm (3.15 in) busbar
Dimensions and mass 100 mm (3.94 in)W × 224 mm (8.82 in)H × 35 mm (1.38 in)D, 600 g (21.2 oz), cord length: 3 m (9.84 ft)
Accessories Instruction manual ×1

Â