CLAMP ON PROBE
3276
10 mA order current waveforms
Wideband Current Probe for Oscilloscopes
Exclusive Academic Offer
Hioki wide frequency current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The 3276 offers a wide DC to 100 MHz bandwidth and 30A of continuous input, and applications include capturing transient current signals from switching power supplies, inverters, and motor controllers.
The probe is designed with a high permeability magnetic shield with low insertion loss to reduce derating that may result from increased sensor head heating caused by eddy currents, making it ideal for measuring current of low impedance circuits and waveforms that include high frequency components.
Key Features
âĒ Waveform observation across a wide band from DC to MHz
âĒ Connects directly to oscilloscope or Memory HiCorder BNC input terminal *1
âĒ High S/N characteristics enable the measurement of 10 mA order current waveforms
*1 Connecting the deviceâs metal BNC terminal to a Memory HiCorderâs plastic BNC terminal may damage the plastic terminal or cause it to become misshapen.
Model No. (Order Code)
3276 | DC to 100 MHz, 30 Arms |
---|
Note: Use the Power Supply 3269/3272 for general measurements or when power is not available from the Memory Hicorder. When performing continuous measurements, be aware of offset voltage drift.
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months)
Frequency bandwidth | DC to 100 MHz (-3 dB) |
---|---|
Rise time | 3.5 ns or shorter |
Noise level | 2.5 mA rms max. (bandwidth limited to 20 MHz) |
Continuous allowable input | 30 A rms (requires derating at frequency) |
Max. allowable peak input | 50 A peak (non continuous) |
Amplitude accuracy (30 min. after power-on, after degaussing and zero-adjustment) | Âą1.0 % rdg. Âą1 mV f.s. (DC, 45 to 66 Hz, 0 to 30 A rms) Âą2 % rdg. (DC, 45 to 66 Hz, 30 A rms to 50 A peak) |
Output rate | 0.1 V/A (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1MÎĐ) |
Measurable conductors | Insulated conductor |
Core diameter | Ï 5 mm (0.20 in) |
Power supply | Âą12 V Âą0.5 V, 5.3 VA max. |
Dimensions and mass | 175 mm (6.89 in)W Ã 18 mm (0.71 in)H Ã 40 mm (1.57 in)D, 240 g (8.5 oz) Sensor cable BNC terminal: 1.5 m (4.92 ft), Power cable: 1 m (3.28 ft) |
Accessories | Instruction manual Ã1, Carrying case à 1 |